How do we calculate?
Wall thickness for pressure t = P × D ÷ (2 × σ × e) + c (Barlow). σ is the allowable stress (yield × ratio), e the weld efficiency, c the corrosion allowance. The minimum thickness for handling and installation is taken as (D + 508) ÷ 400 mm. The larger of the two is rounded up to a standard plate thickness.
Let us turn your calculation into a bill of materials
Send us the list from the calculator; we will quote flanges, elbows, tees, reducers, pipes and valves in a single offer, with EN 10204 3.1 material certificates.
This calculator is used in these sectors: Hydropower. All calculators →
Results are for preliminary selection and do not replace engineering design. Ask our technical team for the final selection.